Technical Parameters
Working temperature:<40°C
Supply voltage: AC115V~230V
Output: 24 channels * 1W/350mA
External dimension: L358*W251*H82mm
Gross weight: 3.7kg
Power consumption: 100W
External Dimension
Panel introduction
Direction for use
DMX address code settings
When no DMX signal access, the default power-on LED displays "S -", press the "Menu" button, will display the current DMX address code.Press Up or Down modify the DMX address code (001-512).
Static color choices
DMX address code changes in the mode, press the Menu button again, select the items that enter the static mode.A total of 20 static mode, label from C01-C20, can be Up or Down switch.
Gradient mode selection
Static mode, press the Menu button to select the items that enter the gradient mode.A total of 9 gradient mode, label from the F01-F09, through the Up or Down keys to switch.In this mode, press the Menu button for 3 seconds long, gradual speed changes into the state.Speed grade gradient was the fastest from the 01 ~ 99,01, 99, was the slowest.Press the Menu button again to confirm the changes and return.
DMX mode selection
When the digital display "S -", press the Up or Down button to select the appropriate DMX mode (S1x, S2x, S3x independent, Sx0 and Sx1 two opposites, the two can only be one), press the Menu button confirm and exit.DMX DMX signal when there are lights flashing access, DMX signal is off (or switch signal line is allocated to the host state), lights out.
S10: PORT with console ports of all lamps on the overall control (power-on default state).
S11: PROT console port on different light on the independent control.
Example: while select S30 mode (master off) and S20 models, and address code is 1, select the S10 model, the control station 1 to 3 channel RGB control of all ports PORT dimming.If you choose to S11, are 1 to 3 channel control RGB dimming port PORT1, 4 to 6 channel dimmer control PORT2 port RGB, and so on.
S20: RGB 3-channel dimmer (power-on default state).
S21: In this mode all the way out, DMX console to take 5 channels.If the address code is 1, then 1 to 3 channels for the RGB independent dimming, the fourth channel is the overall dimming RGB, 5-channel control the rate of change in tone color strobe.
S30: Master Off (power-on default state).Select the state, it can receive DMX signals.
S31: Master Open.Select the state, DMX control is turned off, the controller is disabled to receive DMX signals.While "Master" lights on.
Typical applications