LN-TY-C is produced by our company independently developed a solar controller,it is mainly used for solar power generation system, used to control the multi-square solar cells to charge the battery and the battery to the low-voltage load (such as LED lights) or the inverter device for power control equipment. Use high-speed MCU controller and high-precision A / D conversion, battery charging and discharging of the precise control; It has many advantages such as a battery over-discharge, overshoot, anti-charge, trickle charge and so on.
Main features
Technical parameters
Model |
LN-TYCON-C-DCxV |
|
Rated charging current |
10A |
|
Rated discharging current |
10A |
|
Rated Voltage |
12V/24V Auto |
|
No load losses |
<7mA |
|
Charging circuit voltage drop |
Less than or equal to 0.26V |
|
Discharge circuit voltage drop |
Less than or equal to 0.15V |
|
Over voltage protection |
17V, x2/24V |
|
Promote charge voltage |
14.6V, x2/24V (time of duration: 30 minutes)(call when discharge, or call every 7days) |
|
Direct charge voltage |
14.4V, x2/24V (time of duration: 30 minutes) |
|
Float charge voltage |
13.6V, x2/24V(time of duration: until fell to return to battery charge) |
|
Charge recover voltage |
13.2V, x2/24V |
|
Over discharge recover voltage |
12.5V, x2/24V |
|
Lower voltage indication |
12.0V, x2/24V |
|
Over discharge voltage |
11.1V, x2/24V |
|
Temperature compensation |
-5mV/°C/2V(boost voltage, direct charge, float charge and charge return voltage compensation) |
|
Control method |
PWM Smart Charging |
|
Light controll illumination |
10lux(20 seconds) |
|
Working temperature |
From -35°C to +65°C |
|
Controller protection |
Over-charge, over-discharge, over-current protection , Solar battery, Anti-connection-reverse protection for storage battery and TVS Lightning protection. |
All the protections are harmless to any parts and fuse of controller |
External Dimention
Interface Specifications
Load working mode and discharge duration Settings
This controller has changed load output mode and discharge duration changed function.
Two load working modes: lighting control and lighting&timing control , it is choose through the different connection mode, that as the photo of Interface Specifications, the connection mode are load(lighting control) and load(lighting control & delay). Two load mode can choose only one or also use two, but when the two modes are choose as output, total load output current is not more than rated voltage.
The change of discharge duration through button the control panel of the controller, 4 delay time optional: 2 hours, 4 hours, 6 hours, 8 hours. Each click buttons, long delay switch to the next choice, indicator light will indicate the choose item. The set of discharge duration only useful below the load output mode of lighting control & delay.
Indicator shows
state
Indicator light |
Off |
On |
Strobe |
Charge Indicator |
Not charging |
Charging |
System error (stop working) |
Discharge Indicator |
Not discharging |
Discharging |
Typical Application
Applied circuit 1: Load discharge mode is lighting control
Applied circuit 2: load discharge mode is lighting control & delay.