Place of Origin | shenzhen |
---|---|
Brand Name | Okled |
Model Number | LP100-W1V12 |
Inquiry |
100W 5V/12V/24V Waterproof IP67 power supply
Plastic Shell IP67 Waterproof Series
100w 12vdc output, 100-240vac input
led switching power supply/lighting transformer
( Package: 1 x LP100-W1V12 )
Product Feature
1. Plastic shell IP67 waterproof series, mainly used in LEDs fields.
2. Waterproof IP67, widely used outdoor or indoor with large of water vapor.
3. Full of 100% pure glue, best for cooling, no fan design and quiet.
4. 100% full load burn-in test. Usable 50W ~ 100W but advise 50W ~ 80W.
5. Protections: short circuit, over load, over voltage, over temp.
Product View
LP 100W | |||||||||
FEATURES | |||||||||
100% full load burn-in test | |||||||||
Universal AC input | |||||||||
Small size and high efficiency | |||||||||
Conform to EMC EN5502 GB9254 | |||||||||
Built-in EMI filter with tiny ripple | |||||||||
Comply with the safety standards GB4943 IEC60950-1 EN60950-1 | |||||||||
Protection: short circuit/over current/over load/over temperature | |||||||||
MODEL | LP100-W1V12 | LP100-W1V24 | |||||||
OUTPUT | DC VOLTAGE | 12V | 24V | ||||||
VOLTAGE TOLERANCE | ±5% | ±5% | |||||||
RATED CURRENT | 8.3A | 4.2A | |||||||
CURRENT RANGE | 0-8.3A | 0-4.2A | |||||||
RATED POWER | 100W | 100W | |||||||
RIPPLE& NOISE (MAX.) | 100mVp-p | 120mVp-p | |||||||
POWER FACTOR(Typ.) | 0.6 | 0.6 | |||||||
INPUT | VOLTAGE RANGE | 100-240VAC | |||||||
FREQUENCY RANGE | 50/60 Hz | ||||||||
AC CURRENT(Typ.) | 1A/115V, 0.5A/230V | ||||||||
EFFICIENCY(Typ.) | 84% | 85% | |||||||
COLD START CURRENT | 40A/AC230V | ||||||||
SETUP, RISE, HOLD UP TIME | 100ms, 50ms, 20ms | ||||||||
NO-LOAD CURRENT | <10mA/240VAC | ||||||||
PROTECTION | OVER LOAD | hiccup 105%~150% of the rated power 100W, | |||||||
recovers automatically after fault condition is removed | |||||||||
OVER CURRENT | hiccup over the maximum rated current, | ||||||||
recovers automatically after fault condition is removed | |||||||||
SHORT CIRCUIT | hiccup short circuit, | ||||||||
recovers automatically after fault condition is removed | |||||||||
OVER TEMP | hiccup the Rectifier ≥85°C, | ||||||||
recovers automatically after temperature fall to environment temp | |||||||||
ENVIRONMENT | WORKING TEMP | –20°C~+60°C (no frost) | |||||||
WORKING HUMIDITY | 20%~90%RH | ||||||||
STORAGE TEMP | –40°C~85°C | ||||||||
STORAGE HUMIDITY | 10%~95%RH | ||||||||
SAFETY&EMC | SAFETY STANDARDS | CE, ROHS | |||||||
WITHSTAND VOLTAGE | I/P-O/P: 1.5KVAC/1min, I/P-F/G: 1.5KVAC/1min, O/P-F/G: 0.5KVAC/1min | ||||||||
EMC TESTING STANDARD | EN55022:2010; EN61000-3-2:2014; EN61000-3-3:2013;EN55024:2010+A1:2015 | ||||||||
EN61347-1:2008+A1:2011+A2:2013; EN61347-2-13:2014 | |||||||||
REMARK | 1. The above mentioned data were measured at 220VAC input and 25°C. | ||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated | |||||||||
with a 0.1uf & 47uf parallel capacitor. |